Sacramento, CA · Licensed CA / NV / AZ / WA

Preserving AgingInfrastructure

Corrosion Integrity is a design-build corrosion engineering firm. We survey, design and install the cathodic protection that keeps pipelines, storage tanks and concrete infrastructure in service — and we run the non-destructive testing that proves it is fit for service.

Fig. 1 — ICCP cross-section Structure-to-soil potential −0.912 V
Impressed current Steel structure Anode ground bed Active corrosion cell Criterion −850 mV CSE

Fig. 2 — Storage tanks

Same principle, inside the tank.

On a water storage tank the electrolyte is the water itself. Titanium wire anodes hang from the roof on insulated suspension leads, current spreads through the column onto the shell and floor, and a permanent reference cell reports what the steel is actually seeing — without draining the tank to find out.

Fig. 2 — Water storage tank ICCP Structure-to-water potential −0.964 V
Impressed current Steel shell and floor Titanium wire anode Permanent reference cell Criterion −850 mV CSE

Fit for service

An asset is either fit for service, or it is on a clock. We tell you which.

Corrosion Integrity evaluates infrastructure to determine whether the asset is fit for service, what its remaining useful life is, and whether it can continue to operate safely. Every answer comes from measurement — soil resistivity, structure-to-soil potential, wall thickness, coating adhesion — not from inspection by eye.

0+
Years combined engineering experience
0+
Years in corrosion engineering & construction
0
NDT & coating test methods in-house
0
States licensed — CA · NV · AZ · WA

Sectors served

Water & wastewater Nuclear Oil & gas Petroleum refining & distribution Electric power generation Bridges & tunnels Pier & piling Offshore marine structures Aqueducts Agriculture Government agencies Private industry

Capabilities

Engineer it, assess it, build it — under one point of contact.

Design-build means the engineer who specifies the system is accountable for the crew that installs it. One contact owns the schedule, the budget and the deliverables.

Engineering services

Soil resistivity surveys, laboratory corrosivity analysis, cathodic protection and monitoring system design, plans and specifications.

  • Cathodic protection design — galvanic and impressed current
  • Above-grade storage tanks and clarifiers
  • Atmospheric corrosion assessment
  • Reinforced concrete corrosion control
  • Coatings and paints consulting and inspection
  • Internal corrosion — coupons, LPR and ER probes
  • Interference and stray current studies
  • Corrosion failure analysis
  • Material selection for corrosive environments

Condition assessment

A comprehensive engineering report on the reliability of your facility, built from direct inspection, indirect monitoring and NDT — customizable to your expectations.

  • Assessments that follow or exceed ASTM standards
  • Remaining useful life (RUL) of each asset
  • Repair-or-replace recommendations, prioritized
  • Facility Condition Index (FCI) benchmark
  • Renewal and replacement cost estimates
  • Strategic repair, replacement and modernization plan
  • Preventive maintenance and capital planning
  • Referenced to ACI, ASTM, API, ISO and AMPP (NACE)

Construction & project management

Multimillion-dollar design-build delivery across nuclear, oil & gas, municipal and private sector work. Turn-key, with a site visit before the estimate.

  • Anode ground beds — distributed and deep well
  • Storage tank cathodic protection installation
  • Integrity digs and pipeline excavation
  • Rectifier, RMU and test station installation
  • Hydrovac and key holing services
  • AC mitigation and grounding wells
  • Submersible anode sled installation
  • Tank wash-down, cleaning and disinfection

Inspection & NDT

Twelve ways to find metal loss before it finds you.

Our engineers and technicians run these methods in-house, each assigned to a project by forensic specialty. Select a method for what it detects and where we apply it.

Ultrasonic thickness

$0BEstimated annual damage

It is estimated that more than $30 billion in corrosion damage occurs in water and wastewater handling systems every year.

Pipelines, storage tanks and treatment plants carry most of it. Cathodic protection, correctly designed and actually monitored, is the cheapest line item on the ledger — and the one most often skipped.

Talk through your asset

The criterion

Minus 850 millivolts is the line.

Cathodic protection is judged against a number, not an opinion. Drag the potential and watch where the steel sits.

−0.950VCSE Protected

Pipe wall — indicative surface condition
nominal wall
Reference
Cu / CuSO4 (CSE)
Criterion
−850 mV, IR-free
Measured
Instant-off or coupon

Illustrative only — a real assessment needs an IR-free potential and wall thickness data.

Reference Cell — TanksReference cells

Reference Cell — Tanks

Permanent cell for structure-to-electrolyte potential monitoring inside storage tanks and clarifiers.

Quoted
Mag Rod AnodeAnodes

Mag Rod Anode

Magnesium rod for galvanic systems — tank interiors, small structures and retrofit protection.

Quoted
Canistered Wire AnodeAnodes

Canistered Wire Anode

Canistered wire anode for deep well and distributed ground beds where soil conditions demand depth.

Quoted
PV DC Current ControllerPower & control

PV DC Current Controller

Solar-driven current control for impressed current systems where grid power is not available.

Quoted
GrommetTank hardware

Grommet

Sealed cable penetration for tank roofs and hand holes.

Quoted
Phenolic Test BoardTest stations

Phenolic Test Board

Anode current testing and shunt terminations — the point where the system gets measured.

Quoted
Sacrificial Test StationTest stations

Sacrificial Test Station

Flush or above-grade station for potential and current testing, opening for access to the terminations.

Quoted

See the full catalog →

0 items in quote

Safety & training

Our foundation is safety. Our people are certified to prove it.

We invest in employee development and in the reporting culture that keeps hazards visible before they become incidents.

Built on dedication to safety

Corrosion Integrity's success and foundation is built on our dedication to safety. Crews carry current certifications, and every project runs safety observation reporting and hazard identification.

NCCERVeriforceMEA ISNetworldOSHA Safety observation reportingHazard ID program

Classes & certifications

API RP 578 — Material Verification Program

API 578 gives guidelines for a Material Verification Program (MVP) to confirm the correct chemical composition of alloy materials in new and existing process piping systems across oil, gas and petrochemical service.

  • Purpose — establish a quality assurance system for material verification, preventing wrong material installation that leads to accelerated corrosion or component failure.
  • Scope — ferrous and nonferrous alloy materials in new and existing process piping systems and equipment.
Call (213) 336-5867 for availability

Coverage

Headquartered in Sacramento. Mobilized across the West.

Two offices, four licensed states, and crews that mobilize to the asset rather than waiting for it to come to them.

Northern California office

Pleasant Grove, CA3837 Howsley Rd
Pleasant Grove, CA 95668

Northern Arizona office

Flagstaff, AZFlagstaff, AZ 86001

Licensed operations

CaliforniaNevadaArizonaWashington

Additional operations in the Midwest and Southwest.

Licenses & registrations

  • CSLB #1057714 — Engineering A, C57
  • AZ ROC #337772
  • DIR #1000421416
  • MBE & WBE #22000141
  • SBE #2025728

Service request

Tell us what you are protecting.

We visit the site before we estimate. Send the structure, the environment and what you already know — an engineer will come back to you, not a call centre.

Northern California

3837 Howsley Rd
Pleasant Grove, CA 95668

Northern Arizona

Flagstaff, AZ 86001